Pressure Transmitter
Brief Description3151GP pressure transmitter adopts advanced-technology high-accurate compact smart sensor, to compensate temperature and static pressure with digital compensation technology which improves measuring accuracy and decreases temperature drift. With long-term
DetailsFeatures
Microprocessor makes it more flexible and powerful;
With strong self-diagnose performance, zero and range regulation don’t influence each other;
With perfect remote and local set and calibration functions;
Two-wire system which is in accordance with HART PROTOCOL, can communicate with HART PROTOCOL terminal without interrupting output;
Digital compensation which can compensate to temperature and static pressure;
With good stability performance and high-accuracy, damping is adjustable, strong one-way overload resistant capacity;
Without mechanical driving components which reduce maintenance, solid and vibration-resistant;
Components are in common use which is easy for maintenance;
Wetted parts diaphragm material is optional and can be used for a day long.
Technical Parameters
Output signal: 4~20mAoutput with HART® protocol digital signal(two-wire system)
Power supply: Outside power24V DC, (power range 12V~45V)
Installation: Explosion-proof dⅡCT5, intrinsic safety iaⅡCT5
Drift features: Range upper and lower limit shall not exceed range limit after positive and negative drift. Maximum positive drift is 0.975URL, maximum negative drift is-URL at minimum range.
Temperature range: medium temperature -40~104℃, storage temperature -40~85℃, working temperature -40~85℃/-20~70℃ (with digital head)
Relative humidity: 0~100%
Damping: time constant within 0.2~32.0S is adjustable
Start time: 3S, no need to preheat
Performance: under standard test conditions like without drift, 316stainless steel isolation diaphragm etc.
Range ratio: 40:1
Accuracy: range is 3, 4, 5
Range ratio is 1:1 to 10:1, ±0.1% of calibration range
Range ratio is 10:1 to 40:1, ±0.05(1+0.1URL/range)% of range
Range is 6, 7, 8, 9, 0
Range ratio is 1:1 to 10:1, ±0.15% of calibration range
Range ratio is 10:1 to 40:1, ±0.075(1+0.1URL/range)% of range
Stability: error in six months is ±0.15% of maximum range
Over pressure influence: error in six months is ±0.15% of maximum range after being added 140kgf/cm²
Power supply influence: less than 0.005%/V of output range
Vibration influence: frequency is 200Hz at any axial direction; error is ±0.05%/g of maximum range
Load influence: provided voltage input transmitter is higher than 12V, there will be no load influence within load working area
Mounting influence: maximum zero error is more than 0.25 kPa, but adjustable without influence to range, when you measure body, there will be no influence to flange rotary.
Model
| 3151GP | Intelligent Pressure Transmitter | |||||||||||
|
| code | Gauge pressure range(KPa) | Absolute pressure range(KPa) | |||||||||
| 1 | 0-0.15~7.5 | 0-0.15~7.5 | ||||||||||
| 2 | 0-4~40 | 0-4~40 | ||||||||||
| 3 | 0-2~200 | 0-2~200 | ||||||||||
| 4 | 0-7~700 | 0-7~700 | ||||||||||
| 5 | 0-21~2100 | 0-21~2100 | ||||||||||
| 6 | 0-70~7000 | 0-70~7000 | ||||||||||
| 7 | 0-210~21000 | 0-210~21000(special range is customized) | ||||||||||
| 8 | 0-420~41000(special range is customized) |
| ||||||||||
|
| code | Output | ||||||||||
| A | 4-20mA standard output | |||||||||||
| H | 4-20mA+HARTprotocol | |||||||||||
| F | FF bus protocol | |||||||||||
|
| code | Flange joint | Vent valve | Isolation diaphragm | Filling | |||||||
| 22 | 316SS | 316SS | 316SS | Silicon oil (normal) | ||||||||
| 23 | 316SS | 316SS | Hastelloy C | |||||||||
| 24 | 316SS | 316SS | Monel | |||||||||
| 25 | 316SS | 316SS | Tantalum | |||||||||
| 33 | Hastelloy C | Hastelloy C | Hastelloy C | |||||||||
| 35 | Hastelloy C | Hastelloy C | Tantalum | |||||||||
| 44 | Monel | Monel | Monel | |||||||||
|
| code | Connection | ||||||||||
| O | 1/4NPT F | |||||||||||
| T | 1/2NPT F | |||||||||||
| S1 | With one remote device(positive pressure side) | |||||||||||
|
| code | Display | ||||||||||
| D | Digital head | |||||||||||
| M | Digital head with set button | |||||||||||
| N | Without head | |||||||||||
|
| code | Mounting bracket | ||||||||||
| B1 | Bend bracket pipe mounting 2" | |||||||||||
| B2 | Bend bracket plate mounting | |||||||||||
| B3 | Flat bracket pipe mounting 2" | |||||||||||
|
| code | Explosion performance | ||||||||||
| Ex | Explosion-proof | |||||||||||
| id | Intrinsic-safety | |||||||||||
| 3151GP | □ | □ | □ | □ | □ | □ | □ |
| ||||

To learn more,please click below video which is a little slow firstly,just be patient and waiting!