3151DP/GP pressure (differential pressure) transmitter adopts advanced-technology high-accurate compact smart sensor, to compensate temperature and static pressure with digital compensation technology which improves measuring accuracy and decreases temper
Output signal: 4~20mAoutput with HART® protocol digital signal(two-wire system)
Power supply: Outside power24V DC, (power range 12V~45V)
Installation: Explosion-proof dⅡCT5, intrinsic safety iaⅡCT5
Drift features: Range upper and lower limit shall not exceed range limit after positive and negative drift. Maximum positive drift is 0.975URL, maximum negative drift is-URL at minimum range.
Temperature range: medium temperature -40~104℃, storage temperature -40~85℃, working temperature -40~85℃/-20~70℃ (with digital head)
Relative humidity: 0~100%
Performance: under standard test conditions like without drift, 316stainless steel isolation diaphragm etc.
Model
3151DP | Differential Pressure Transmitter with remote flange | |||||
3151GP | Pressure Transmitter with remote flange | |||||
| code | Range | ||||
3 | 0-0.12~7.5 kPa | |||||
4 | 0-0.40~40 kPa | |||||
5 | 0-2~200 kPa | |||||
6 | 0-7~700 kPa | |||||
7 | 0-21~2100 kPa | |||||
8 | 0-70~7000 kPa | |||||
| code | Output | ||||
E | 4~20 Ma,with HART protocol digital signal | |||||
| code | Pressure chamber Plug Isolation diaphragm | ||||
22 | 3166ST 3166ST 3166ST | |||||
| code | Remote flange | ||||
S1 | With one Remote flange | |||||
| code | Accessories | ||||
M4 | Multi-function LED head |