Pressure Controller
Pressure Controller
Brief Description

D511-7D pressure controller has bellows sensor, can be used in neutral gas and water like air, gas and water steam as well as liquid medium like water, oil and cryogen, setting value is adjustable, adjust range is -0.1-6.3MPa, mainly used in nuclear power

Details

 

Main Technical Parameters

Applicable to corrosive air, gas, water, hydraulic oil, lubricant oil, cryogen, light fuel oil, etc.

Working viscosity: <1×10-3m2/s

Housing protection: IP65(DIN40050)

Environment temperature: -25~40℃

Medium temperature: 0~120℃

Joint direction: pressure joint is vertically downward

Vibration-resistant: Max:20m/s2

Repeatability error:≤1.5%

Contact capacity: DC 250V 0.25A(resistance)60 Wmax  

               AC 250V 5A(resistance)1250 Wmax

 

Technical Parameters

 D511/7D switch difference is not adjustable

MPa(kPa) Setting value adjustment

Switch value Less than MPa(kPa)

Mpa (kPa) Max

allowable

Switch times of switches

Sensor material

Joint

weight kg

Overall dimension

Size

Drawing No

Ordering Catalog No

 

lower limit of setting value

upper limit of setting value

 

Cover

Diaphragm

Ordinary

Ordinary Type

 

-0.1~0

-0.1~0.1

-0.1~0.16

-0.1~0.25

0.006

0.007

0.008

0.009

0.007

0.008

0.009

0.012

1

1

1

1

20

copper

stainless steel OOGr17Nit4MO ²

(316L)

Other:

1Gr18Ni9Ti All wetted parts are stainless steel bellow tube

G1/2"

G1/2"

G1/2"

G1/2"

1.0

1.0

1.0

1.0

01

01

01

01

08100111

08100211

08100311

08100411

 

0~0.1

0~0.16

0.01~0.25

0.007

0.008

0.009

0.008

0.009

0.01

1

1

1

G1/2"

G1/2"

G1/2"

1.0

1.0

1.0

01

01

01

08101111

08101211

08101311

 

0.02~0.4

0.03~0.6

0.03~1

0.03

0.03

0.03

0.03

0.035

0.04

2

2

2

G1/2"

G1/2"

G1/2"

0.85

0.85

0.85

02

02

02

08101411

08101511

08101611

 

0.05~1.6

0.05~2.5

0.07

0.07

0.08

0.09

5

5

G1/2"

G1/2"

0.9

0.9

03

03

08101711

08101811

 

0.3~6.3

0.1

0.2

8.5

G1/2"

0.9

03

08101911

 

 D511/7D switch difference is adjustable

MPa(kPa) Setting value adjustment

Switch value Less than

Mpa (kPa) Max

allowable

Switch times of switch

Sensor material

Joint

weight kg

Overall dimension

Size

Drawing No

Ordering Catalog No

 

MPa(kPa) lower limit of setting value

MPa(kPa)

upper limit of setting value

 

Cover

Diaphragm

Ordinary

Ordinary Type

 

-0.1~0

-0.1~0.1

-0.1~0.16

-0.1~0.25

0.018~0.08

0.019~0.1

0.02~0.2

0.022~0.25

0.019~0.08

0.021~0.1

0.022~0.2

0.024~0.25

1

1

1

1

20

copper

stainless steel OOGr17Nit4MO ²

(316L)

Other:

1Gr18Ni9Ti All wetted parts are stainless steel bellow tube

G1/2"

G1/2"

G1/2"

G1/2"

1.0

1.0

1.0

1.0

01

01

01

01

08100111

08100211

08100311

08100411

 

0~0.1

0~0.16

0.01~0.25

0.015~0.08

0.018~0.1

0.02~0.25

0.016~0.08

0.02~0.1

0.024~0.25

1

1

1

G1/2"

G1/2"

G1/2"

1.0

1.0

1.0

01

01

01

08101111

08101211

08101311

 

0.02~0.4

0.03~0.6

0.03~1

0.08~0.25

0.08~0.5

0.09~0.8

0.08~0.25

0.09~0.5

0.1~0.8

2

2

2

G1/2"

G1/2"

G1/2"

0.85

0.85

0.85

02

02

02

08101411

08101511

08101611

 

0.05~1.6

0.05~2.5

0.17~1.2

0.18~2

0.19~1.2

0.2~2

5

5

G1/2"

G1/2"

0.9

0.9

03

03

08101711

08101811

 

0.3~6.3

0.25~2

0.65~2

8.5

G1/2"

0.9

03

08101911