Explosive-proof pressure controller
Explosive-proof pressure controller
Brief Description

D501/7D explosion-proof series pressure controller has diaphragm type sensor, can be used in corrosive gas and liquid, setting value range is 0~2.5MPa, sensitivity is high in low pressure area.

Details

Technical Parameters

Used in corrosive medium as well as gas and water, hydraulic oil, lubricating oil, light fuel oil etc

Working viscosity: <1×10-3m2/s

Housing protection: IP65(DIN40050)

Environment temperature: -25~40℃

Medium temperature: 0~120℃

Joint direction: pressure joint is vertically downward

Vibration-resistant: Max:20m/s2

Repeatability error: ≤1.5%

Contact capacity: DC 250V 0.25A(resistance)60 Wmax   

              AC 250V 5A(resistance)1250 Wmax

Explosion: ExdeIICT4~CT6.

Specifications

D501/7D switch difference is not adjustable

Setting value Range

 MPa (KPa)

 

Switch difference

not more than

Rated

Pressure

*MPa

Switch freq-

uency

Sensor material

Female thread

Weight

Kg

Overall

size

Ordering

 No.

 

Setting value Range lower limit MPa (KPa)

Setting value Range

Upper limit MPa (KPa)

Hous-

ing

Diaph-

ragm

(0-2.5)

(0 - 6)

(0- 16)

(0- 25)

(0.3)

(0.4)

(0.4)

(0.4)

(0.4)

(0.6)

(0.8)

(0.9)

0.1

10

304

316L

G1/4”

G1/4”

G1/4”

G1/4”

1.5

01

0855180

0855280

0855380

0855480

0.005-0.06

0.005-0.1

0.005-0.16

0.005-0.25

0.003

0.003

0.003

0.004

0.006

0.009

0.012

0.015

1.5

G1/4”

G1/4”

G1/4”

G1/4”

1.5

02

0855580

0855680

0855780

0855880

0.03-0.4

0.03-0.6

0.05-1

0.02

0.03

0.03

0.04

0.05

0.06

10

G1/4”

G1/4”

G1/4”

0.8

03

0853580

0853680

0853780

0.1-1.6

0.1-2.5

0.04

0.04

0.12

0.15

G1/4”

G1/4”

0.8

0853880

0853980

D501/7D switch difference is adjustable

Setting value Range

 MPa

difference

not more than

Rated

Pressure

*MPa

Switch freq-

uency

Sensor material

Female thread

Weight

Kg

Overall

size

Ordering

 No.

 

Setting value Range lower limit MPa (KPa)

Setting value Range

Upper limit MPa (KPa)

Hous-

ing

Diaph-

ragm

(0-2.5)

(0-6)

(0-16)

(0-25)

(0.8-2.5)

(0.9-4)

(1.1-12)

(1.1-20)

(1.1-2.5)

(1.5-4)

(2.3-12)

(2.8-20)

0.1

10

 

304

316L

G1/4”

G1/4”

G1/4”

G1/4”

1.5

01

0845180

0845280

0845380

0845480

0.005-0.06

0.005-0.1

0.005-0.16

0.005-0.25

0.009-0.05

0.011-0.08

0.013-0.12

0.014-0.2

0.016-0.05

0.018-0.08

0.025-0.12

0.025-0.2

1.5

G1/4”

G1/4”

G1/4”

1.5

02

0845580

0845680

0845780

0845880

0.03-0.4

0.03-0.6

0.05-1

0.05-0.2

0.06-0.4

0.06-0.6

0.08-0.2

0.1-0.4

0.11-0.6

10

**

G1/4”

G1/4”

G1/4”

0.8

03

0843580

0843680

0843780

0.1-1.6

0.1-2.5

0.12-1.2

0.12-2

0.25-1.2

0.33-2

G1/4”

G1/4”

0.8

0843880

0843980

Note: during working, instant pressure peak value can note exceed this value in *, ** is static pressure.