Magnetic Electric Contact Pressure Gauge
Magnetic Electric Contact Pressure Gauge
Brief Description

YXC-102 Magnetic assistant electric contact pressure gauge is widely used in oil, chemical industry, metallurgy and power plant or matched with electromechanical equipment to measure inexplosive liquid pressure. Generally speaking, this gauge can control

Details

Main Technical Parameters 

Types

Model

Name

Range

MPa

Accuracy

Thread

size

Reading

Set value

on

Off

General type

YXC-100

*YXC-102

YXC-103

Magnetic

Electric

Contact

Pressure

Gauge

From   0~0.6 to 60;

From-0.1~0.06

To 2.4

1.5

1.5

4

M20*1.5 (*G3/8”) (*G½”)

 

YXC-150

*YXC-153

From   0~0.1 to 60 & from

-0.1~0 to 2.4

Dedicated type

YXCA-150

Ammonia Pressure

Gauge

From 0~0.16 to 60 & from

-0.1~0.06  to

2.4

2.5

2.5

4

Anti-vibration

 

YXC-100-Z

*YXC-102-Z YXC-103-Z

 

Magnetic

Electric

Contact

Pressure

Gauge

From  0~0.6 to 60 & from

-0.1~0.5    to

2.4

1.5

 

1.5

 

5

 

 

Corrosion resistant

*YXC-100B-F

*YXC-102B-F

*YXC-103B-F

*YXC-150B-F

*YXC-152B-F

From 0~0.16 to 60 & from

-0.1~0.06  to

2.4

1.5

1.5

4

Anti-vibration

& corrosion resistant

*YXC-100B-FZ

*YXC-102B-FZ

*YXC-152B-FZ

*YXC-153B-FZ

From   0~0.6 to 60 & from

-0.1~0.5    to 2.4

1.5

1.5

5

Isolated general Isolated corrosion

resistant

YXCG-103

 

*YXCG-130-F

Isolated

Magnetic

Electric

Contact

Pressure

Gauge

From 0~0.16 to 60 & from

-0.1~0.06  to

2.4

1.5

1.5

4

M42*2 (*G1

¼”)

Isolate

anti-vibration

YXCG-103Z

From   0~0.6 to 60 & from

-0.1~0.5    to 2.4

1.5

1.5

5

Isolated

Anti-vibration

& corrosion resistant

*YXCG-103FZ

Working Environment

Types

Temp range

Relative humidity

Working  vibration

performance

medium

Ambient

General    & dedicated

-40~70℃

≤85%

V.H.3

Corrosion-resistant

-25~55℃

≤90%

V.H.3

Anti-vibration,

corrosion-resistant

V.H.4

Isolated general

<150℃

-40~70℃

V.H.3

Isolated corrosion-resistant

-40~70℃

Isolated other type

<150℃

-25~55℃

V.H.4

Temp influence: indicating value is not more than 0.4%10℃, set value is not more than 0.6%10℃,
(operation temp deviation :20±5℃)

Structure principle

This gauge consists of measuring system, indicating device, magnetic assistant electric contact device, casing, adjusting device and junction box (socket) etc. Working principle is that the spring end will shift under pressure of measured medium, assisted by vane, driven by wheel gear and amplified, and then the indicating needle fixed on the wheel gear axis will indicate the measured value on the scale plate. Meanwhile, at the moment it contacts the set needle contactor (upper limit or lower limit), the circuit of the system will be on or off to control and send signal.