YXC-153B-FZ Magnetic assistant electric contact pressure gauge is widely used in oil, chemical industry, metallurgy and power plant or matched with electromechanical equipment to measure inexplosive liquid pressure. Generally speaking, this gauge can cont
Main Technical Parameters
Types | Model | Name | Range MPa | Accuracy | Thread size | ||
Reading | Set value | ||||||
on | Off | ||||||
General type | YXC-100 *YXC-102 YXC-103 | Magnetic Electric Contact Pressure Gauge | From 0~0.6 to 60; From-0.1~0.06 To 2.4 | 1.5 | 1.5 | 4 | M20*1.5 (*G3/8”) (*G½”)
|
YXC-150 *YXC-153 | From 0~0.1 to 60 & from -0.1~0 to 2.4 | ||||||
Dedicated type | YXCA-150 | Ammonia Pressure Gauge | From 0~0.16 to 60 & from -0.1~0.06 to 2.4 | 2.5 | 2.5 | 4 | |
Anti-vibration
| YXC-100-Z *YXC-102-Z YXC-103-Z
| Magnetic Electric Contact Pressure Gauge | From 0~0.6 to 60 & from -0.1~0.5 to 2.4 | 1.5
| 1.5
| 5
| |
Corrosion resistant | *YXC-100B-F *YXC-102B-F *YXC-103B-F *YXC-150B-F *YXC-152B-F | From 0~0.16 to 60 & from -0.1~0.06 to 2.4 | 1.5 | 1.5 | 4 | ||
Anti-vibration & corrosion resistant | *YXC-100B-FZ *YXC-102B-FZ *YXC-152B-FZ *YXC-153B-FZ | From 0~0.6 to 60 & from -0.1~0.5 to 2.4 | 1.5 | 1.5 | 5 | ||
Isolated general Isolated corrosion resistant | YXCG-103
*YXCG-130-F | Isolated Magnetic Electric Contact Pressure Gauge | From 0~0.16 to 60 & from -0.1~0.06 to 2.4 | 1.5 | 1.5 | 4 | M42*2 (*G1 ¼”) |
Isolate anti-vibration | YXCG-103Z | From 0~0.6 to 60 & from -0.1~0.5 to 2.4 | 1.5 | 1.5 | 5 | ||
Isolated Anti-vibration & corrosion resistant | *YXCG-103FZ |
Working Environment
Types | Temp range | Relative humidity | Working vibration performance | |
medium | Ambient | |||
General & dedicated | -40~70℃ | ≤85% | V.H.3 | |
Corrosion-resistant | -25~55℃ | ≤90% | V.H.3 | |
Anti-vibration, corrosion-resistant | V.H.4 | |||
Isolated general | <150℃ | -40~70℃ | V.H.3 | |
Isolated corrosion-resistant | -40~70℃ | |||
Isolated other type | <150℃ | -25~55℃ | V.H.4 |
Temp influence: indicating value is not more than 0.4%10℃, set value is not more than 0.6%10℃,
(operation temp deviation :20±5℃)
Structure principle
This gauge consists of measuring system, indicating device, magnetic assistant electric contact device, casing, adjusting device and junction box (socket) etc. Working principle is that the spring end will shift under pressure of measured medium, assisted by vane, driven by wheel gear and amplified, and then the indicating needle fixed on the wheel gear axis will indicate the measured value on the scale plate. Meanwhile, at the moment it contacts the set needle contactor (upper limit or lower limit), the circuit of the system will be on or off to control and send signal.