WRN-440 Explosion-proof and intrinsic safety type thermocouple is a temperature sensor, widely applied in the chemical industrial automatic control system. It transfers the object temperature to electrical signal, and sends it to display, record and adjus
In chemical plant, the production field is often accompanied with various inflammable, explosive chemical gas & steam, it’s not safe to use common thermocouple which is easy to result in gas explosion. Therefore, explosion-proof and intrinsic safety type thermocouple is necessary. Our explosion-proof and intrinsic safety type thermocouple are used in these dangerous occasions of which temperature group zone are dII BT4 ~ dII CT6, ib II BT4, ia ll BT4, ia ll CT6.
Model | Graduation | Range ℃ | Accuracy | Allowable deviation |
WRN,WRNK WRN2,WRNK2 |
K | 0~800℃ | I | ±1 5℃ or ±0. 004 t |
Ⅱ | ±2.5℃ or ±0.0075t | |||
WRE,WREK WRE2,WREK2 |
E |
0~600℃ | I | ±1.5℃ or ±0.004t |
Ⅱ | ±2 5℃ or ±0 0075 t |
Specifications
Model | Graduation | Range ℃ | Specs | Response time T 0.5s | Nominal pressure MPa | Structure | Exd grade | ||
Total length Lmm | Insert Depth l mm | ||||||||
NiCr-NiSi | WRN-240 WRN2-240 | K | 0-800 |
| 150 200 250 300 400 500 750 1000 1500 2000 | ≤90 | 10 | Exd Head
Fixed thread M27×2 | dⅡBT4 dⅡBT6 or dⅡCT4 dⅡCT6 |
NiCr-CuNi | WRE2-240 WRE-240 | E | 0-600 | ||||||
NiCr-NiSi | WRN-640 WRN2-640 | K | 0-600 | 150 200 250 | 30 | Tapper protection tube, Fixed thread M33×2 | |||
NiCr-CuNi | WRE-640 WRE2-640 | E | 0-600 | ||||||
NiCr-NiSi | WRN-440 WRN2-440 | K | 0-800 | 150 200 250 300 400 500 750 1000 1500 2000 | 6.4 | Exd head Fixed flange | |||
NiCr-CuNi | WRE-440 WRE2-440 | E | 0-600 |
Notes: Exd flange is instrument standard JB/t5219-1991, is RFW