Bimetal Thermometer
Bimetal Thermometer
Brief Description

Protection tube, joint and locking bolt of WSSX series bimetallic thermometer are 1cr18ni9ti stainless steel, the case is made of stretched aluminum board after machining, surface is dealt with electrophoresis processing, the head (cover and box) is ring

Details

Technical Parameters

Temperature range: 60-500 ℃

Accuracy: 1.5. Contactor action error limit is 1.5tiims of readings basic error. .

Thermometer dial diameter: 60, 100, 150 mm.

Tube length: 75-2000mm.

Tube diameter: 6, 8, 10 (when tube length is 100-1250); 12 (when tube length is 1250-2000mm).

Install thread: M16X1.5, M27X2, G1/2, G3/4, tube and fixed bolt joint are1 cr18ni9ti stainless steel, pressure 6.4 MPa.

Waterproof performance: the shell can withstand spray from 25mm-faucet 5m away (water pressure is not less than 2Kg/m²), no water penetrate the thermometer case within 5minitues.

Housing: IP65

Contact rated power: 10 VA

Contact maximum operating voltage: ~ 380 v or 220 v

Contact maximum working current: 1 a (non-inductive load)

Working voltage should be between 15V and 48V.

Model

W

S

S

specification

 

 

 

 

-

 

 

3

ø60

4

Ø100

5

Ø150

Dial nominal diameter

0

Angle or axial type

1

Straight or radial type

8

Universal type

5

Angle type with hot jacket

6

Straight type with hot jacket

7

Universal type with hot jacket

structural style

1

Movable male thread

2

Movable female thread

3

Movable Flange

Mounting type

 

W

S

S

-