         Bimetal Thermometer with Thermal Resistance
Bimetal Thermometer with Thermal Resistance 
    
  Brief Description
Brief DescriptionWSS-481PH2 bimetallic thermometer with thermocouple (resistance) and temperature transmitter is a temperature sensor for local display and remote signal transmission. It can indicate local temperature as well as transmit two-wire system signal of thermoco
 Details
DetailsTechnical parameters
Measuring range: -60 ~ 500 ℃
Display accuracy: 1.5
Remote signal deviation:
A. Graduation: E (nickel chromium-copper nickel) allowable deviation ± 2.5 ℃ or 0.75% t
B. Graduation: K (nickel chrome-nickel silicon) allowable deviation ± 2.5 ℃ or 0.75% t
C. Graduation: Pt100 platinum resistor () allowable deviation:
Class A: ± (0.15 + 0.002 ∣ t ∣)
Class B: - (0.30 + 0.005 ∣ t ∣)
D. Basic error with temperature transmitter: Δ = Δ 1 + / - 0.5% FS
Δ 1 is thermocouple (resistance) basic error, FS is measuring range
Temperature transmission: two-wire system (4 ~ 20 mA), transmitter minimum working voltage is 12V, maximum 35 V, rated voltage 24V
Work environment:
A. environmental temperature: -25 ℃ ~ 80 ℃ (not higher than 70 ℃ in dangerous place)
B. relative humidity: 5% ~ 95%
C. mechanical vibration: f≤55Hz, amplitude < 0.15 mm
D. no corrosive medium in the environment
Environment temperature influence: ≤0.05%/1℃
Model
| W | S | S | Specifications | |||||||
| Temperature Instrument | Metal expansion type | bimetallic | - | 
 | 
 | |||||
| 
 | 4 | 
 | Φ100mm | |||||||
| 5 | 
 | Φ150mm | ||||||||
| Dial nominal diameter | 0 | 
 | Angle or axial type | |||||||
| 1 | 
 | Straight or radial type | ||||||||
| 8 | 
 | Universal type | ||||||||
| structural style | 1 | 
 | Movable male thread | |||||||
| 2 | 
 | Movable female thread | ||||||||
| 3 | 
 | Movable Flange | ||||||||
| Mounting type | thermocouple | 
 | 
 | |||||||
| E | 
 | nickel chrome- Copper nickel, type E | ||||||||
| N | 
 | Nickel chrome- nickel silicon, type K | ||||||||
| Thermal resistance | 
 | 
 | ||||||||
| Pt100 | 
 | Platinum resistance | ||||||||
| Cu50 | 
 | Copper Resistance | ||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | Sensor | 
 | Without temperature transmitter | |
| H2 | The output and the temperature is in linear | |||||||||
| H4 | Output and input signal is in linear | |||||||||
| temperature transmitter | 
 | |||||||||
| W | S | S | - | □ | □ | □ | □ | □ | 
 | |

 
                    
                    
                    	 
                    
                    
                    	 To learn more,please click below video which is a little slow firstly,just be patient and waiting!