SBW temperature transmitter with industrial thermocouple and thermal resistance is a field-installed temperature transmitter unit of DDZ series instruments. It combines thermocouple or thermal resistance with transmitter together to measure temp
Model and Specifications
Temperature transmitter with thermocouple and thermal resistance
Model | Graduation | Range ℃ |
SBWR-2180 | E | 0~400 0~600 |
SBWR-2280 | K | 0~400 0~600 0~800 0~1000 |
SBWR-2380 | S | 600~1600 |
SBWR-2880 | N | 0~400 0~600 0~800 0~1000 0~1200 |
SBWR-4180 | E | 0~600 |
SBWR-4280 | K | 0~1100 |
SBWR-4380 | S | 0~1600 |
SBWR-4480 | B | 0~1600 |
SBWR-4580 | T | 0~400 |
SBWR-4880 | N | 0~1200 |
SBWR-2180 | Cu50 | -50~150 |
SBWR-2280 | Cu100 | -50~150 |
SBWR-2480 | Pt100 | 0~500 |
-100~200 | ||
SBWR-4480 | Pt100 | -200~500 |
Note: special specification is customized
Model
S | B | W | specifications |
| ||||||||||||
|
| Temperature |
|
| General type | |||||||||||
R |
| Thermal resistance | ||||||||||||||
Z |
|
| Thermocouple | |||||||||||||
| - |
|
| |||||||||||||
| 2 |
| Output and corresponding temperature in linearity | |||||||||||||
4 |
| Output and corresponding input signal in linearity | ||||||||||||||
Output | 0 |
| General type | |||||||||||||
Thermocouple |
|
| ||||||||||||||
1 |
| E NiCr-CuNi | ||||||||||||||
2 |
| K NiCr-NiSi | ||||||||||||||
3 |
| S PtRh10-Pt | ||||||||||||||
4 |
| B PtRh30-PtRh6 | ||||||||||||||
5 |
| T Cu-CuNi | ||||||||||||||
6 |
| J Fe-CuNi | ||||||||||||||
8 |
| N NiCrSi-NiSi | ||||||||||||||
Thermal resistance |
|
| ||||||||||||||
1 |
| Cu50 | ||||||||||||||
4 |
| Pt100 | ||||||||||||||
Sensor | 7 |
| Isolation type with temperature element | |||||||||||||
8 |
| Non-isolation type with temperature element | ||||||||||||||
Circuit | 0 |
| Standard | |||||||||||||
1 |
| Smart | ||||||||||||||
2 |
| Digital Display | ||||||||||||||
3 |
| Needle type | ||||||||||||||
4 |
| Smart display | ||||||||||||||
5 |
| Smart needle | ||||||||||||||
6 |
| With HART | ||||||||||||||
| / |
|
| |||||||||||||
| 2 |
| Fixed thread | |||||||||||||
4 |
| Fixed flange | ||||||||||||||
6 |
| Fixed thread taper tube | ||||||||||||||
8 |
| Female thread | ||||||||||||||
9 |
| Thermowell tube | ||||||||||||||
Mounting | 4 |
| Explosion-proof | |||||||||||||
Junction box | S |
| PT100 | |||||||||||||
0 |
| Thermocouple | ||||||||||||||
1 |
| insulation(sheathed) | ||||||||||||||
2 |
| Shell(sheathed) | ||||||||||||||
| 3 |
| Tri-type | |||||||||||||
| K |
| Sheathed | |||||||||||||
| d | Explosion-proof | ||||||||||||||
i | Intrinsic safe | |||||||||||||||
|
| |||||||||||||||
S | B | W | □ | - | □ | □ | □ | □ | / | □ | □ | □ | □ | □ | □ |
|