CPDF Series insertion type Magnetic flow meter from CEPAI is inductive meter which measures conductive medium volume flow based on Faraday’s Law of Magnetic Induction. Single chip embedded technology, digital excitation and CAN fieldbus are top class. Mag
Features
Simple structure, reliable, without movable elements, long service life;
No cut-off or choke elements, no pressure loss and flow-blocking;
Measuring accuracy is not effected by medium and its temperature, viscosity, density and pressure;
Lined with PTFE or rubber, electrode material Hc, Hb and Ti are available, which can be applicable to different medium;
With several models like pipeline type and insertion type;
With EEPROM memory unit, measuring and computing data which is reliable and safe;
With two types, integrated type and separated type;
LCD display with high definition;
Technical Parameters
Accuracy: pipeline type, class 0.5 and class 1.0; insertion type, class 2.5;
Medium: liquid and mixed liquid with conductivity more than 5μS/cm;
Flow velocity: 0.2~8m/s
Environment temperature: -40℃~+50℃
Medium temperature: PTFE line, not more than 180℃;
Rubber line, not more than 65℃;
Explosion-proof: ExmibdⅡBT4
Magnetic interference: ≤400A/m
Housing: integrated, IP65;
Separated, sensor IP68 (underwater 5m, limited to rubber line), converter IP65
Output signal: 4~20mA.DC, load 0~750Ω
Communication output: RS485 or HART
Electric connection: M20×1.5F, cable hole-DN10