Y-200general pressure gauge measures pressure of medium like liquid, vapor and gas that are safe without danger, no crystallization, no solidification, and doesn’t corrode steel, copper and copper alloy.It has different mounting types like radial type, ra
Structure Principle
Measurement system includes joint, bourdon tube and driving mechanism, reading through needle.
Parameters
Model | Y-40 Y-40Z | Y-60 Y-60Z Y-60ZT | Y-100 Y-100ZT | Y-150 Y-150ZT | Y-200 Y-250 |
DN mm | ¢40 | ¢60 | ¢100 | ¢150 | ¢200,¢250 |
Joint thread | M10*1 | M14*1.5 | M20*1.5 | ||
Accuracy | 2.5 | 1.5 | |||
Measuring range MPa | 0~0.1; 0.16; 0.25; 0.4; 0.6; 1; 1.6; 2.5; 4; 6 | 0~0.6; 1; 1.6; 2.5; 4; 6 | |||
0~10; 16; 25 | 0~10; 16; 25; 40; 60 | ||||
-0.1~0 | -0.1~0; -0.1~0.06; 0.15; 0.3; 0.5; 0.9; 1.5; 2.4 |
Working environment condition: -40~70℃, relative humidity is not more than 85%
Temperature influence: not more than 0.4%/10℃(working temperature deviation is 20±5℃)
Materials of main parts
Name | Joint | Spring tube | Movement | Shell |
No. of material | Copper alloy HPb59-1 | Phosphor copper QSn4-0.3 | Copper alloy | Steel board 0.8F |
Reference Operating Condition
Basic error, return difference, friction error and needle deviation stability is in accordance with GB/T1226-2010 under the following condition:
a) Environment temperature: 20℃±5℃
b) Gauge is under normal working condition
c) Uniform load change
Note: normal working position is vertical mounting if without notice.
Temperature influence: not more than 0.4%/10℃(operating temperature deviation 20±5℃)
Execution standard: GB/T1226-2010
Operating temperature: 40℃~70℃
Vibration-resistant class: V.H.3