Type 9220 Explosion Proof Type Solenoid Valve can works without lubrication, or can supply anti-rust engine oil or equivalent. The service life is more than 10 millions times, Namur standard 3/2 and 5/2 is compatible with terminal box of long service life
Products Feature:
1, small volume,large flow rate.
2, work without lubrication, easy to maintenance.
3, easy to installation, please try to select the installation position which vibrates lightly.
4, plate type solenoid valve, 3/2 and 5/2 can be compatible only after adjusting the seal ring.
Parameter of Explosive-proof Coil
Rated Voltage | AC220V 50HZ | DC24V |
Allowed Range of Voltage | ±15% | ±15% |
Starting Current | 22mA | 59mA |
Power | 3.2W | 3W |
Temperature of Coil | 15℃ | 35℃ |
Parameter of Typical Coil
Rated Voltage | AC110V | AC220V | DC12V、DC24V | |
Allowed Range of Voltage | ±15% | ±15% | ±15% | |
Starting Current | 50HZ | 25mA | 50mA | 84mA |
60HZ | 30mA | 60mA | 101mA | |
Working Current | 50HZ | 7mA | 12mA | 22mA |
60HZ | 8.4mA | 15mA | 27mA | |
Rated Power | 50HZ | 7.5W | 7.5W | 5W |
60HZ | 8W | 8W | 5.5W |
Model
Model | Mode of action | Type of Control | Working Voltage | Explosive-proof Class | Type of Installation |
9210 | 3 3/2way
5 5/2way | 1 single electrical control
2double electrical control | 1 AC48V 2 AC110V 3 AC240V 4 AC220V 5 DC24V | M casting seal and explosive proof
I Exia | D pipe type
N NAMUR |